Add a system
A system is a technical installation, such as a ventilation unit or a heat pump. A single unit can serve multiple systems, and a single system can use multiple units.
Written By Evolo Support
Last updated 6 days ago
Create a system
Systems are located under Configuration → Systems on the building.
Click New System.
Fill in:
Code (optional): for example,
=360.001. The equals sign is optional; the code is saved the same way regardless.Name and Category, for example, Air Handling or Heating.
Optionally, location, manufacturer, year of installation, operational description, and maintenance.
Click Save.
The system automatically creates a separate folder under Documents in FDV.
Create a system from a template
A template creates units, interfaces, data points, logging, alarms, and, if applicable, a view for a known facility, already connected to a new system.
Go to Systems and click New System.
Select the template in Template (optional). The discipline, manufacturer, operational description, and maintenance information are populated from the template, and you can edit them.
Enter the Code and Name.
Select Gateway.
For each device: enter the Device Name and IP address.
For each interface: enter the Unit ID (Modbus) or Device ID (BACnet).
Check the Create View box if the template has a view and you want to include it.
Click Create.
Data points and alarms will have the system code prefixed to their names, for example, “=360.001-Supply Air Temperature.” Without a code, the device name is used. This allows you to have multiple identical systems in the same building.
Check the values after creation, for example using the integration test. The software version in the system may differ from the template. If you find an error in one of Evolo’s templates, please notify support.
Suggest Systems
If you have created data points without a system, the “Systems” button will display “Suggest systems.” Evolo identifies TFM codes in the names of devices and data points, such as “360.001 Ventilation,” “=360.001-RT401,” and retrieves the discipline from the code (36 is air handling).
Click “Suggest Systems.”
Review the suggestions. Devices without a code are suggested as separate systems but are not selected.
Click Create. The data points are linked to the systems, and you can change the names and disciplines afterward.
Export and Import Systems
Export downloads the systems as an Excel spreadsheet. Use it as a starting point to enter multiple systems at once, and upload it using Import:
Evolo The system is recognized by its Code, or by its Name if the Code field is empty.
The system already exists: the row updates the fields. A template in the row is ignored.
New system with a template: Select a template from the Template column. Units, data points, and alarms are created from the template. Enter the IP address and Unit ID / Device ID, and select a gateway when importing.
New system without a template: only the system is created.
Save a system as a template
If you’ve set up a facility you want to use again, save it as a template:
Go to Systems and select Save as Template from the context menu for the system.
Select New Template and enter the name, manufacturer, and description, or select Update Existing and choose the template to update. The version number will then be incremented by one.
If desired, select View based on the template.
Click Save.
The system code, unit name, and addresses of the units are removed from the template so it can be used for another building.
The Templates tab displays the templates from all the organizations you are a member of, plus Evolo’s templates. The Organization column shows who the template belongs to.
Link data points to a system
You can connect existing data points to a system from the tables. Data points from a template are already disconnected.
All data points on an interface:
Go to Configuration → Interface.
Click Set System in the System column, or click the system listed there.
Select Existing System, or New System and enter the code and name.
Click Save. All data points on the interface are linked to the system.
Selected data points:
Go to Configuration → Data Points.
Check the boxes next to the data points.
Click Selected and select Set System.
Select a system and click Save.
Select "Remove Link" to remove the data points from the system. The data point table has a "System" column, and you can filter by system, including "No System."